| PTF | New | Superceded | Problem Description |
|---|---|---|---|
| UQ40137 | UQ44498 | Sample install jobs EQZRDP41 and EQZRDPTS fail with RC=08. | |
| UQ42271 | Telephony Base for OS/390 does not allow the use of characters < and >. | ||
| UQ43067 | UQ44498 | The supplied sample JCL in EQZSCTAJ was incorrect. | |
| UQ44498 | Sample macro EQZTSCT has some assembler continuation characters missing in column 72. | ||
| UQ45953 | CICS RDO defintions missing for programs EQZ1IPGV and EQZ1PCA. | ||
| UQ53058 | CallPath/CICS V2R1M0 - Program Data is not encoded/decoded from EBCDIC to ASCII. | ||
| UQ55053 | SMP/E APPLY for CallPath/CICS V2R1M0 fails in a V1 SMP/E environment. | ||
| UQ62011 | * | Provide support for GENESYS CALLPATH 6.4 and TSERVER | |
| UQ67115 | * | Convert CALLPATH/CICS to have one request handler per switch | |
| UU07240 | After UQ67115, SubSystem fails on READ NEXT error if switches are defined as auto-start | ||
| UU07270 | After UQ67115, transaction EQRH requires TWASIZE=100 | ||
| UU07340 | * | New API, STLMONC, used to monitor CDR messages attached to a current call. It includes new CDR messages. | |
| ***** NOTE: All PTFs above this point are included in CallPath/CICS Version 2.2 ***** | |||
| UU07420 | * | FIX FOR STORAGE VIOLATION ON SWITCH SHUTDOWN | |
| UU07450 | Fix encoding for API STLPCA in Callpath/CICS | ||
| UU07490 | Receiving message IEC070I for EQZLOGA which indicates that the log file is full. Also, not submitting the archive jobs. | ||
| UU07620 | Fix address exception abend which occurs as a result of initializing parameters not used by Callpath/CICS | ||
| UU07680 | When autostart executes in Callpath/CICS, the switch fails to restart without shutting down the subsystem or the CICS region. | ||
| UU07770 | When shutting down a switch through CP/CICS, there currently are no stop monitors being issued at the CICS level. The switch is stopped and a release is issued to CP/Server and the stop monitors are issued at the CP/Server level. It is possible to restart the switch and issue the start monitors prior to the completion of all the stop monitors by CP/Server. This can cause resources to be unmonitored even when the switch is restarted and the start monitors are issued. **NOTE: THIS PTF IS USED IN ASSOCIATIION WITH UU07780 IN CALLCOORDINATOR/CICS WHICH MUST ALSO BE LOADED. THIS WILL ALSO INCREASE THE TIME IT TAKES FOR THE SWITCH TO SHUTDOWN FROM CALLPATH/CICS. | ||
| UU07840 | The primary and secondary space limits for table EQAMQ (Application Message Queue) have been increased from 1000 to 4000. | ||
| UU07890 | Currently the switch shutdown procedure is synchronous and, because the stop monitors are now issued, will freeze the keyboard in Callpath/CICS or CallCoordinator/CICS. This can be a very lengthy time process if there are a lot of monitors for a particular switch. NOTE: PTF UU07900 must also be added to CallCoordinator if this is used. | ||
| UU08020 | When the Callpath/CICS journal files are full, they should always swap automatically. This is not occurring due to a program problem. | ||