CallPath/CICS - V 2 Service Updates

PTF List

Last Updated: 2006/02/23

Note: If a PTF has been superceded, it is recommended that the newer (superceding) PTF be used.

* in New field indicates new function

PTF  New Superceded Problem Description
UQ40137   UQ44498 Sample install jobs EQZRDP41 and EQZRDPTS fail with RC=08.
UQ42271     Telephony Base for OS/390 does not allow the use of characters < and >.
UQ43067     UQ44498 The supplied sample JCL in EQZSCTAJ was incorrect.
UQ44498     Sample macro EQZTSCT has some assembler continuation characters missing in column 72.
UQ45953     CICS RDO defintions missing for programs EQZ1IPGV and EQZ1PCA.
UQ53058     CallPath/CICS V2R1M0 - Program Data is not encoded/decoded from EBCDIC to ASCII.
UQ55053     SMP/E APPLY for CallPath/CICS V2R1M0 fails in a V1 SMP/E environment.
UQ62011 *   Provide support for GENESYS CALLPATH 6.4 and TSERVER
UQ67115 *   Convert CALLPATH/CICS to have one request handler per switch
UU07240     After UQ67115, SubSystem fails on READ NEXT error if switches are defined as auto-start
UU07270     After UQ67115, transaction EQRH requires TWASIZE=100
UU07340   *   New API, STLMONC, used to monitor CDR messages attached to a current call. It includes new CDR messages.
***** NOTE: All PTFs above this point are included in CallPath/CICS Version 2.2 *****
UU07420   *   FIX FOR STORAGE VIOLATION ON SWITCH SHUTDOWN
UU07450     Fix encoding for API STLPCA in Callpath/CICS
UU07490     Receiving message IEC070I for EQZLOGA which indicates that the log file is full. Also, not submitting the archive jobs.
UU07620     Fix address exception abend which occurs as a result of initializing parameters not used by Callpath/CICS
UU07680     When autostart executes in Callpath/CICS, the switch fails to restart without shutting down the subsystem or the CICS region.
UU07770     When shutting down a switch through CP/CICS, there currently are no stop monitors being issued at the CICS level. The switch is stopped and a release is issued to CP/Server and the stop monitors are issued at the CP/Server level. It is possible to restart the switch and issue the start monitors prior to the completion of all the stop monitors by CP/Server. This can cause resources to be unmonitored even when the switch is restarted and the start monitors are issued. **NOTE: THIS PTF IS USED IN ASSOCIATIION WITH UU07780 IN CALLCOORDINATOR/CICS WHICH MUST ALSO BE LOADED. THIS WILL ALSO INCREASE THE TIME IT TAKES FOR THE SWITCH TO SHUTDOWN FROM CALLPATH/CICS.
UU07840     The primary and secondary space limits for table EQAMQ (Application Message Queue) have been increased from 1000 to 4000.
UU07890     Currently the switch shutdown procedure is synchronous and, because the stop monitors are now issued, will freeze the keyboard in Callpath/CICS or CallCoordinator/CICS. This can be a very lengthy time process if there are a lot of monitors for a particular switch. NOTE: PTF UU07900 must also be added to CallCoordinator if this is used.
UU08020     When the Callpath/CICS journal files are full, they should always swap automatically. This is not occurring due to a program problem.

Send mail to CallPath/CICS and CallCoordinator/CICS Level 2 Support


Return to CallPath Support Home Page